In a pre-war Williamsburg tenement with one-pipe steam, rooms that don't heat usually have clogged or failed air vents — the vent is what allows air to escape so steam can enter the radiator. A stuck-closed vent means the radiator fills with air and never heats. Replacing the vent with a correctly-sized one (larger radiators need higher-capacity vents) almost always restores heat to that room. It's a common, low-cost fix in Williamsburg's walk-up buildings.
Post-2000 Williamsburg loft conversions were typically replumbed from scratch during the conversion, so the supply and drain systems are modern — copper or PEX supply, PVC or cast-iron waste. The main variables are the heating system (hydronic radiant, fan coil, or individual mini-split units are all common) and whether the unit has its own water heater or draws from a central building system. Your offering plan and the building's management office can confirm the system type. For in-unit plumbing repairs or fixture work, we work in Williamsburg loft buildings regularly.